HotXLS Docs

TXLSXChartErrBar class

Unit: lxHandleX
Chart error-bar settings (direction, value type, no-end-cap flag, value and plus/minus components) attached to a TXLSXChartSeries

Description

Chart error-bar settings (direction, value type, no-end-cap flag, value and plus/minus components) attached to a TXLSXChartSeries The class is part of the XLSX facade (lxHandleX) and is reached through the owning workbook or worksheet; instances are not normally created directly by application code

Properties

Direction
BarType: TXLSXChartErrBarType selection of xlsxErrBarBoth, xlsxErrBarPlus, xlsxErrBarMinus or xlsxErrBarUnknown; new instances default to Both
ValueType
NoEndCap
Value
PlusValue
MinusValue
PlusRange, MinusRange: independent one-dimensional local A1 custom error references
PlusCache, MinusCache: read-only collection properties returning independently owned TXLSXChartDataCache objects

Error side identity

BarType retains native both, plus or minus identity through reading, structured writing, clone and assignment; a custom single-sided error requires only its applicable side's data

Unknown, absent or incorrectly cased wire identity remains Unknown, preserving unmodified opaque imports while refusing a structured rewrite

The setter uses the workbook write guard and rejects out-of-range enum values without changing state

See single-sided portable errors for supported geometry and endpoint/cap conventions

Line visibility and hidden restoration

LineVisible: Boolean defaults to True and participates in existing write guards, clone state and semantic identity

Setting False captures the current supported appearance and writes the hidden restoration profile; setting True restores it and removes that extension

A visible main line ignores a stale memento, and a later hide captures the current main properties instead

While hidden with a restoration memento, LineColorSet, LineWidthSet, LineColorRGB and LineWidthPoints access that restoration state; explicit setters persist changes there, and RGB assignment clears the previous system-color identity

Supported cached system colors retain their standard name and lastClr value, but portable recording uses the cached RGB

A hidden noFill line without a restoration memento remains hidden; making it visible uses its remaining represented width and fallback color

Direct portable capture supports represented unsaved edits while preserving the source model and all other exact chart projection checks

See hidden-line lifecycle and limits for native restoration, unsupported source profiles and scene-width behavior

Stored line appearance

LineStyleSet selects a represented error shape, while LineColorSet and LineWidthSet independently indicate stored RGB and width components; LineColorRGB is a six-digit RGB value and LineWidthPoints is a positive finite width quantized to integer EMU

The stored width range is one EMU through 1584 points; an assignment that rounds below one EMU or exceeds that range rejects without changing state

Clearing a component flag removes only that component on saving, and setting LineStyleSet to False resets the whole shape, both component flags and any unsupported source identity

Read-only LineAppearanceSupported distinguishes complete represented main/restoration RGB or cached-system-color profiles from opaque appearance metadata; unrelated title edits preserve opaque shapes, while direct line edits require an explicit full reset first

With portable error controls enabled, each present stored component overrides its caller fallback independently; portable widths must not exceed 100 points, even though the workbook model supports the wider legal stored range

See stored portable error appearance for supported XML, capture and restoration boundaries

Custom error data and ownership

For custom errors, each numeric cache overrides its scalar side; one index-zero value broadcasts, or a complete contiguous array supplies one value per plotted point

Setting PlusValue or MinusValue explicitly removes that side's range and cached identity, including an assignment equal to the previous scalar value

A different nonempty range clears stale cached values; an empty range retains its cache as literal data

Callers can edit cache points but must not free the owned cache objects; clone copies them deeply, and all edits honor the workbook write guard

AttachOwner(AOwnerChart) rebinds the error bar to its owning chart and forwards the same owner to the owned PlusCache and MinusCache objects, so later cache or range edits resolve the correct workbook write guard

Capture uses existing caches without recalculation; explicitly refresh data caches after source-cell edits or use the existing structured-save refresh path

See portable custom error data for applicability, correspondence, resource and source-appearance limits

See also